ZKT SF100 |
ZKTeco F2 |
I think it's the most valuable topic, together we can test and list the support devices :)) |
|
@caobo171 how about f18 and f21? |
@caobo171 got error with f16: Error: TIMEOUT_ON_WRITING_MESSAGE IP is correct, ping/telnet to port 4370 is success, and there's no other device connecting with this device. Any idea why can't connect? |
can you restart the device and try again |
ZKTeco UA760 |
THAI01 Works mostly, few string issues. |
@pierrejoye Do you have any update on THAI01? |
not working properly with zkteco k70. not getting all records by getAttendances() but the same day record. |
Basically, all UA-* series should be fine. That includes THAI01 (the small version of the UA serie) All WL-* serie models cannot work and are not supported anymore by ZkTeco (be their own software or SDK). If you want to buy devices and try before buying, ask the vendor to test using the ZkTeco Software or SDK latest version, if it works, it should be good. |
Does this work on WL30??Can anyone please tell me. thank you |
@ameik297 see my comment, the full WL Serie does not work. |
Hi sir, |
I tried even using ZkTeco SDK (.net, c or FFI), it does not work. I went to
the zkteco office in town and they confirm only the ones i mentioned in my
comment.
Surely some other may work but I am waiting new arrivals from them to valid
abd test .
Alternatively you could reverse engineer it and provide patch, but it is
then painful :)
…On Mon, May 3, 2021, 2:36 PM ameik297 ***@***.***> wrote:
@ameik297 <https://github.com/ameik297> see my comment, the full WL Serie
does not work.
Hi sir,
Is there no other way to be able to get attendance from WL30 device using
other sdk?
—
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub
<#5 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/AACE6KB47HW4UUU76WJLEALTLZHBRANCNFSM4JTQVMPQ>
.
|
Aww, I see so that's how really it is. Thank you so much for the info sir. |
They don't state it in the SDKs but it is simply does not work. As mentioned earlier, I went to their office and we validated quite a few series, using their SDK (I used FFI with node and go to implement a test), or using their own desktop app. We end up with the list I gave above, which has the same core hardware or firmware more or less. Since I stick to this list, zero issues. |
Hi! Does this work on G series? e.g. Zkteco G1 |
It worked with ZKTeco K20 so far |
This is still maintained? |
F18 |
It worked with ZKTeco DS100 👍🏻 |
ZKTeco F22/M is okay, real time logs isnt working tho |
tested with F18 as well, works nicely I think |
Everyone should comment with devices this has worked on: