List of stove-commands
######################
### RC200057 ### --> ?
### RC300058 ### --> ?
### RC400059 ### --> [returns 0000]
### RC50005A ### --> [returns 0004, maybe target fan speed? / power level]
### RC60005B ### --> stored target temperature
### RC70005C ### --> ?
### RC80005D ### --> ?
### RC90005E ### --> ?
### RD000056 ### --> exaust gas temperature (first 4 chars)
### RD100057 ### --> ambient temperature (first 4 chars)
### RD200058 ### --> speed of exaust vent
### RD300059 ### --> speed of ambient vent
### RD40005A ### --> speed of pellet snail
### RD50005B ### --> ? correction of exhaust speed (always 0...)
### RD60005C ### --> Reset error state
### RD70005D ### --> ???
### RD80005E ### --> countdown cycle (first 4 chars)
### RD90005F ### --> status
0000 0020 --> off
0101 0022 --> ignition 1 (fan acc)
0102 0023 --> ignition 2 (load wood)
0103 0024 --> ignition 3 (fire on)
0104 0025 --> ignition 4 (fire on + vent on)
0201 0023 --> on
0801 0029 --> cooling 1 (normal)
0802 002A --> cooling 2 (normal)
1001 0022 --> cooling 1 (for stand-by)
1002 0023 --> cooling 2 (for stand-by)
1003 0024 --> off (stand-by)
### RDA00067 ### --> Error code
0000 0020 --> No error
0005 0025 --> No flame
### RDB00068 ### --> filling state sucking sensor
### RDC00069 ### --> firmware-version [returns 9200]
### RDD0006A ### [returns 0000]
### RDE0006B ### [returns 0000]
### RDF0006C ### --> PCB temperature
[...]
### REF0006D ### --> exhaust fan rpm (first 4 digits hex to dec *10)
[...]
### RF000058 ### --> power off
### RF001059 ### --> power on [MAY BE POWER-LEVEL!!! RF00x0yy -> 0 = off, 1 ... 5 power level x, 6 may be "AUTO"]
### RF00x0yy ### --> set power level
### RF2xx0yy ### --> set target temperature